		<article-meta>
		<article-id pub-id-type="other">4</article-id>
			<article-id pub-id-type="doi">10.19053/01211129.v33.n67.2024.17362</article-id>
			<article-categories>
				<subj-group subj-group-type="heading">
					<subject>Articles</subject>
				</subj-group>
			</article-categories>
			<title-group>
				<article-title>Development of an Application for Calculating the Power Flow of Bipolar DC Networks Using the MATLAB Environment</article-title>
				<trans-title-group xml:lang="es">
					<trans-title>Desarrollo de una aplicación para el cálculo del flujo de potencia en redes DC bipolares utilizando el entorno de MATLAB</trans-title>
				</trans-title-group>
				<trans-title-group xml:lang="pt">
					<trans-title>Desenvolvimento de uma aplicação para cálculo de fluxo de potência em redes DC bipolares utilizando o ambiente MATLAB</trans-title>
				</trans-title-group>
			</title-group>
			<contrib-group>
				<contrib contrib-type="author">
					<contrib-id contrib-id-type="orcid">0000-0001-6051-4925</contrib-id>
					<name>
						<surname>Montoya-Giraldo</surname>
						<given-names>Oscar-Danilo</given-names>
					</name>
					<xref ref-type="aff" rid="aff1">1</xref>
				</contrib>
				<contrib contrib-type="author">
					<contrib-id contrib-id-type="orcid">0000-0003-4978-6094</contrib-id>
					<name>
						<surname>Rocha</surname>
						<given-names>Jhan-Carlos</given-names>
					</name>
					<xref ref-type="aff" rid="aff2">2</xref>
				</contrib>
				<contrib contrib-type="author">
					<contrib-id contrib-id-type="orcid">0000-0002-3053-4877</contrib-id>
					<name>
						<surname>Fontecha-Saboya</surname>
						<given-names>Daniela</given-names>
					</name>
					<xref ref-type="aff" rid="aff3">3</xref>
				</contrib>
			</contrib-group>
			<aff id="aff1">
				<label>1</label>
				<institution content-type="original"> Ph. D. Universidad Distrital “Francisco José de Caldas” (Bogotá-Distrito Capital, Colombia). odmontoyag@udistrital.edu.co. ORCID: 0000-0001-6051-4925</institution>
				<institution content-type="normalized">Universidad Distrital Francisco José de Caldas</institution>
				<institution content-type="orgname">Universidad Distrital “Francisco José de Caldas”</institution>
				<addr-line>
					<city>Bogotá-Distrito Capital</city>
				</addr-line>
				<country country="CO">Colombia</country>
				<email>odmontoyag@udistrital.edu.co</email>
			</aff>
			<aff id="aff2">
				<label>2</label>
				<institution content-type="original"> Universidad Distrital “Francisco José de Caldas” (Bogotá-Distrito Capital, Colombia). jcrochc@udistrital.edu.co. ORCID: 0000-0003-4978-6094</institution>
				<institution content-type="normalized">Universidad Distrital Francisco José de Caldas</institution>
				<institution content-type="orgname">Universidad Distrital “Francisco José de Caldas”</institution>
				<addr-line>
					<city>Bogotá-Distrito Capital</city>
				</addr-line>
				<country country="CO">Colombia</country>
				<email>jcrochc@udistrital.edu.co</email>
			</aff>
			<aff id="aff3">
				<label>3</label>
				<institution content-type="original"> Universidad Distrital “Francisco José de Caldas” (Bogotá-Distrito Capital, Colombia). dfontechas@udistrital.edu.co. ORCID: 0000-0002-3053-4877</institution>
				<institution content-type="normalized">Universidad Distrital Francisco José de Caldas</institution>
				<institution content-type="orgname">Universidad Distrital “Francisco José de Caldas”</institution>
				<addr-line>
					<city>Bogotá-Distrito Capital</city>
				</addr-line>
				<country country="CO">Colombia</country>
				<email>dfontechas@udistrital.edu.co</email>
			</aff>
			<author-notes>
				<fn fn-type="equal" id="fn2">
					<label>Authors Contribution</label>
					<p><bold>Oscar Danilo Montoya-Giraldo:</bold> conceptualization; methodology; data analysis; writing-review and editing. <bold>Jhan-Carlos Rocha:</bold> research; methodology; data analysis; software; writing-original draft. <bold>Daniela Fontecha-Saboya:</bold> research; methodology; data curation; software; writing-original draft.</p>
				</fn>
			</author-notes>
			<pub-date date-type="pub" publication-format="electronic">
				<day>30</day>
				<month>03</month>
				<year>2024</year>
			</pub-date>
			<pub-date date-type="collection" publication-format="electronic">
				<season>Jan-Mar</season>
				<year>2024</year>
			</pub-date>
			<volume>33</volume>
			<issue>67</issue>
			<elocation-id>e17362</elocation-id>
			<history>
				<date date-type="received">
					<day>04</day>
					<month>01</month>
					<year>2024</year>
				</date>
				<date date-type="accepted">
					<day>25</day>
					<month>03</month>
					<year>2024</year>
				</date>
				<date date-type="pub">
					<day>29</day>
					<month>03</month>
					<year>2024</year>
				</date>
			</history>
			<permissions>
				<license license-type="open-access" xlink:href="https://creativecommons.org/licenses/by/4.0/" xml:lang="en">
					<license-p>This is an open-access article distributed under the terms of the Creative Commons Attribution License</license-p>
				</license>
			</permissions>
			<abstract>
				<title>Abstract</title>
				<p>This work proposes the design of a graphic interface to solve the power flow problem in unbalanced bipolar direct current (DC) networks using the successive approximations method. The goal of the graphic interface is to facilitate the user's calculation of the power flow without the need for prior knowledge of programming languages. This work is divided into three stages. The first presents the mathematical power flow model for unbalanced bipolar DC networks using the successive approximations method. The second presents the implementation of the graphic interface, applying the aforementioned mathematical model. The third stage presents the main characteristics of the DC systems under study, in addition to solving the power flow problem through the program and a comparison with the results reported in the specialized literature. Numerical validations demonstrate that the program solves the power flow and finds the same solution as the specialized literature with 100% efficiency, which confirms the program's accuracy and establishes it as a reliable source of information. This document shows the step-by-step creation of the interface, which was tested with two types of networks to corroborate the validity of the program.</p>
			</abstract>
			<trans-abstract xml:lang="es">
				<title>Resumen</title>
				<p>Este trabajo plantea el diseño de una interfaz gráfica para resolver el problema de flujo de potencia en redes bipolares de corriente continua (CC) desbalanceadas mediante el método de aproximaciones sucesivas. El objetivo de la interfaz gráfica es facilitarle al usuario el cálculo del flujo de potencia sin la necesidad de conocimientos previos en lenguajes de programación. Este trabajo está dividido en tres etapas. La primera presenta el modelo matemático de flujo de potencia en redes bipolares DC desbalanceadas mediante el método de aproximaciones sucesivas. La segunda presenta la implementación de la interfaz gráfica, aplicando el modelo matemático mencionado anteriormente. La tercera etapa presenta las principales características de los sistemas DC bajo estudio, además de la solución del problema de flujo de potencia por medio del programa y una comparación con los resultados reportados en la literatura especializada. Las validaciones numéricas demuestran que el programa resuelve el flujo de potencia y encuentra la misma solución de la literatura especializada, con una eficiencia del 100%, lo cual confirma la precisión del programa y lo constituye en una fuente confiable de información. En este documento se muestra el paso a paso de la creación de la interfaz, la cual fue puesta a prueba con dos tipos de redes con el fin de corroborar la validez del programa.</p>
			</trans-abstract>
			<trans-abstract xml:lang="pt">
				<title>Resumo</title>
				<p>Este trabalho propõe o projeto de uma interface gráfica para resolver o problema de fluxo de potência em redes bipolares desequilibradas de corrente contínua (CC) utilizando o método de aproximações sucessivas. O objetivo da interface gráfica é facilitar ao usuário o cálculo do fluxo de potência sem a necessidade de conhecimento prévio de linguagens de programação. Este trabalho está dividido em três etapas. A primeira apresenta o modelo matemático de fluxo de potência em redes DC bipolares desbalanceadas utilizando o método de aproximações sucessivas. A segunda apresenta a implementação da interface gráfica, aplicando o modelo matemático citado acima. A terceira etapa apresenta as principais características dos sistemas CC em estudo, além da solução do problema de fluxo de potência através do programa e uma comparação com os resultados reportados na literatura especializada. As validações numéricas demonstram que o programa resolve o fluxo de potência e encontra a mesma solução na literatura especializada, com eficiência de 100%, o que confirma a precisão do programa e o constitui como uma fonte confiável de informações. Este documento mostra o passo a passo da criação da interface, que foi testada com dois tipos de redes para corroborar a validade do programa.</p>
			</trans-abstract>
			<kwd-group xml:lang="en">
				<title>Keywords:</title>
				<kwd>bipolar direct current networks</kwd>
				<kwd>power flow application</kwd>
				<kwd>successive approximations method</kwd>
				<kwd>unbalanced systems</kwd>
			</kwd-group>
			<kwd-group xml:lang="es">
				<title>Palabras clave:</title>
				<kwd>aplicación de flujo de potencia</kwd>
				<kwd>método de aproximaciones sucesivas</kwd>
				<kwd>redes bipolares de corriente continua</kwd>
				<kwd>sistemas desbalanceados</kwd>
			</kwd-group>
			<kwd-group xml:lang="pt">
				<title>Palavras-chave:</title>
				<kwd>aplicação de fluxo de potência</kwd>
				<kwd>método de aproximações sucessivas</kwd>
				<kwd>redes bipolares de corrente contínua</kwd>
				<kwd>sistemas desequilibrados</kwd>
			</kwd-group>
			<counts>
				<fig-count count="8"/>
				<table-count count="4"/>
				<equation-count count="12"/>
				<ref-count count="29"/>
				<page-count count="0"/>
			</counts>
		</article-meta>
	</front>
	<body>
		<sec sec-type="intro">
			<title>I. Introduction</title>
			<p>Electrical distribution systems are responsible for supplying electricity to all residential, commercial, and industrial users at medium- and low-voltage levels <sup>[</sup><xref ref-type="bibr" rid="B1"><sup>1</sup></xref><sup>]</sup>. These networks are typically operated with alternating current (AC) and are built with a radial topology in order to simplify protection coordination schemes and reduce investment costs <sup>[</sup><xref ref-type="bibr" rid="B2"><sup>2</sup></xref><sup>]</sup>.</p>
			<p>It is necessary for power systems to have high quality, safety, and efficiency indices. However, the increased demand and environmental constraints, as well as the liberalization of electricity markets, have caused them to operate increasingly close to their stability limits <sup>[</sup><xref ref-type="bibr" rid="B3"><sup>3</sup></xref><sup>]</sup>. With the recent advances in power electronics, energy generation systems utilizing non-conventional renewable energy sources, in addition to developing efficient energy storage technologies, are transitioning from passive setups to active networks that interact with the user in an intelligent way <sup>[</sup><xref ref-type="bibr" rid="B4"><sup>4</sup></xref><sup>]</sup>. On the other hand, given the development of energy conversion systems, it is currently possible to implement distribution systems that exclusively use direct current (DC) <sup>[</sup><xref ref-type="bibr" rid="B5"><sup>5</sup></xref><sup>]</sup> and hybrid schemes that leverage the best traits of AC and DC technologies <sup>[</sup><xref ref-type="bibr" rid="B6"><sup>6</sup></xref><sup>]</sup>, providing a better performance in terms of energy losses and voltage profiles <sup>[</sup><xref ref-type="bibr" rid="B7"><sup>7</sup></xref><sup>]</sup>. This is due to the fact that the concepts of reactive power and frequency are non-existent in these networks <sup>[</sup><xref ref-type="bibr" rid="B8"><sup>8</sup></xref><sup>]</sup>, which is why their control schemes are easier to design, as their only task is voltage regulation at the DC busbar <sup>[</sup><xref ref-type="bibr" rid="B9"><sup>9</sup></xref><sup>]</sup>.</p>
			<p>In the case of DC operation technologies, distribution networks can be built with two typical topologies. The first is associated with monopolar networks, i.e., those with a positive pole and a neutral return conductor <sup>[</sup><xref ref-type="bibr" rid="B10"><sup>10</sup></xref><sup>]</sup>. The second corresponds to DC networks with a bipolar topology, i.e., those with a positive and a negative pole as well as a neutral return conductor <sup>[</sup><xref ref-type="bibr" rid="B11"><sup>11</sup></xref><sup>]</sup>. The advantage of a bipolar configuration is that, theoretically, it can transfer twice the power of a monopolar configuration and allows for the connection of loads requiring a voltage level equivalent to twice the power difference between the positive or negative pole and the neutral one <sup>[</sup><xref ref-type="bibr" rid="B12"><sup>12</sup></xref><sup>]</sup>. </p>
			<p>To analyze DC distribution networks with bipolar or monopolar topologies, it is necessary to employ power flow tools, as they allow determining the operating state of a network under steady-state conditions <sup>[</sup><xref ref-type="bibr" rid="B7"><sup>7</sup></xref><sup>]</sup>. However, although there are many reports on the power flow of monopolar networks in the literature <sup>[</sup><xref ref-type="bibr" rid="B13"><sup>13</sup></xref><sup>]</sup>, those on bipolar networks are scarce, and most focus on analyzing the optimal power flow <sup>[</sup><xref ref-type="bibr" rid="B14"><sup>14</sup></xref><sup>]</sup>. Some works on bipolar networks are presented below.</p>
			<p>The authors of <sup>[</sup><xref ref-type="bibr" rid="B11"><sup>11</sup></xref><sup>]</sup> present a multi-objective optimization methodology for phase balancing in bipolar DC distribution systems. However, they fail to consider the presence of constant-power loads and focus solely on constant impedance and current models, which simplifies the power flow problem and allows obtaining mixed-integer linear programming models.</p>
			<p>In <sup>[</sup><xref ref-type="bibr" rid="B14"><sup>14</sup></xref><sup>]</sup>, the authors analyze the effect of asymmetric loads on network congestion, proposing an optimal power flow to obtain marginal prices per node via an equivalent linear formulation.</p>
			<p>The authors of <sup>[</sup><xref ref-type="bibr" rid="B15"><sup>15</sup></xref><sup>]</sup> present a recursive optimal power flow for bipolar DC networks with multiple asymmetric loads. The results of the model are validated in systems with 6 and 33 nodes. The proposed mathematical formulation is developed as a function of the current injection method, and the results are compared against simulations of these networks in the PSCAS/EMTDC. </p>
			<p>The work by <sup>[</sup><xref ref-type="bibr" rid="B16"><sup>16</sup></xref><sup>]</sup> presents a simulation methodology using PSCAD/EMTDC to solve the power flow problem in bipolar networks, for which a three-node test system is employed. However, the authors do not analyze the model’s complexity or a convergence test under load variations. They only alter the constant-power terminals for controlled current sources and leave the complications of the solution to a power system analysis tool.</p>
			<p>The study by <sup>[</sup><xref ref-type="bibr" rid="B17"><sup>17</sup></xref><sup>]</sup> presents the application of a quasi-Newton method for solving the power flow problem in bipolar networks. This method is also known as the Broyden method or the secant, and it ensures a linear convergence to the power flow solution. It is classified as a derivative-free method. The authors validate this methodology in test systems composed of 21, 33, and 85 nodes.</p>
			<p>The work by <sup>[</sup><xref ref-type="bibr" rid="B18"><sup>18</sup></xref><sup>]</sup> presents a generalized methodology for solving the power flow problem in unbalanced bipolar networks, which is based on applying the Newton-Raphson method. A six-node test system is employed to validate the proposed methodology.</p>
			<p>In <sup>[</sup><xref ref-type="bibr" rid="B19"><sup>19</sup></xref><sup>]</sup>, the authors present a methodology for studying the optimal power flow in bipolar networks, which considers a linear approximation of the power flow equations. Numerical results in test systems with 21 and 85 nodes demonstrate that the linear approximation of the power flow is effective insofar as distributed energy resources are considered in bipolar networks.</p>
			<p>Based on the above-presented review of the state of the art regarding power flow for DC networks with a bipolar topology, this article makes the following contributions: (i) in most cases, calculating voltage values requires solving a system of simultaneous nonlinear equations <sup>[</sup><xref ref-type="bibr" rid="B20"><sup>20</sup></xref><sup>]</sup>, which is why the successive approximations method is applied for bipolar networks with either a solidly grounded or a floating neutral wire and monopolar and bipolar loads (this is an extension of the method presented by <sup>[</sup><xref ref-type="bibr" rid="B21"><sup>21</sup></xref><sup>]</sup>); and (ii) this work presents the development of a graphic interface for implementing the successive approximations method in bipolar distribution networks, as a tool of interest for researchers and students in the electrical sector. This is a novel tool for electrical networks of a bipolar nature. It is important to mention that, in the specialized literature, there is no availability of open-access software for this type of application. This was identified as a research opportunity to which this article seeks to contribute significantly. </p>
			<p>The rest of this document is structured as follows. The section titled <italic>Materials and methods</italic> presents the mathematical development of the successive approximations method for bipolar grid applications considering the presence of monopolar and bipolar loads as well as the possibility of having a neutral wire that is either solidly grounded in all nodes or floating. In the <italic>Graphic interface design</italic> section, the main characteristics of the MATLAB application development tool are presented. The section titled <italic>Results and discussion</italic> presents the bipolar configuration of the 21-test feeder used, as well as data on its nodal power consumption and line resistance parameters and the results obtained with the successive approximations method for bipolar networks through its implementation in the developed graphic interface, as well as the corresponding analyses and discussions. Finally, the section titled <italic>Conclusions</italic> describes the main findings of this research, as well as potential research lines. </p>
		</sec>
		<sec sec-type="materials|methods">
			<title>II. Materials and Methods</title>
			<p>This section presents the general methodology regarding the power flow problem for bipolar DC networks, which is based on the successive approximation’s method proposed in <sup>[</sup><xref ref-type="bibr" rid="B22"><sup>22</sup></xref><sup>]</sup>. In addition, it presents the design of a graphic interface in the MATLAB environment for solving the power flow problem in unbalanced radial or meshed networks.</p>
			<sec>
				<title><italic>A. Power Flow Problem Formulation</italic></title>
				<p>In this subsection, matrices will be denoted by capital and italic letters, subscripts will represent nodes, and superscripts will represent iterations.</p>
				<p>The power flow problem for bipolar DC networks employs the grid conductance representation <sup>[</sup><xref ref-type="bibr" rid="B23"><sup>23</sup></xref><sup>]</sup>. The relationship between voltage and current is considered using the nodal admittance matrix.</p>
				<p>
					<disp-formula id="e1">
						<graphic xlink:href="https://revistas.uptc.edu.co/index.php/ingenieria/article/download/17362/version/14852/14307/81680/0121-1129-rfing-33-67-e17362-e1.png"/>
						<label>(1)</label>
					</disp-formula>
				</p>
				<p>Where:</p>
				<p> I 𝑔,𝑝𝑛 is the vector containing all currents injected in the positive and negative poles of the slack nodes. </p>
				<p> 𝐼 𝑑,𝑝𝑛 is the vector containing all demanded currents in the grid’s positive and negative poles. </p>
				<p> 𝐺 𝑝𝑛 is the general conductance matrix that relates the slack and demand nodes. </p>
				<p> 𝐺 𝑔𝑔,𝑝𝑛 is the component of the matrix 𝐺 𝑝𝑛 that relates the slack nodes. </p>
				<p> 𝐺 𝑔𝑑,𝑝𝑛 is the component of the matrix 𝐺 𝑝𝑛 that relates the slack and demand nodes. </p>
				<p> 𝐺 𝑑𝑔,𝑝𝑛 is the transpose of the matrix 𝐺 𝑔𝑑,𝑝𝑛 . </p>
				<p> 𝐺 𝑑𝑑,𝑝𝑛 is the component of the matrix 𝐺 𝑝𝑛 that relates the demand nodes. </p>
				<p> 𝑉 𝑔,𝑝𝑛 is the vector containing all the voltage outputs of the slack nodes. </p>
				<p> 𝑉 𝑑,𝑝𝑛 is the vector containing all the voltages in the demand nodes. </p>
				<p>Note that the second row of <xref ref-type="disp-formula" rid="e1">equation (1)</xref> expresses the relationship between the demand currents and the voltage vectors. This implies that the equation is not linear, as these currents are a function of the demanded voltages and their powers. Therefore, an iterative method is required to solve the power flow problem <sup>[</sup><xref ref-type="bibr" rid="B5"><sup>5</sup></xref><sup>]</sup>.</p>
				<p>To apply the successive approximations method, the second row of <xref ref-type="disp-formula" rid="e1">equation (1)</xref> is reorganized to obtain the voltages of the demand nodes, which was demonstrated in <sup>[</sup><xref ref-type="bibr" rid="B24"><sup>24</sup></xref><sup>]</sup> and is shown in <xref ref-type="disp-formula" rid="e2">equation (2)</xref>.</p>
				<p>
					<disp-formula id="e2">
						<graphic xlink:href="https://revistas.uptc.edu.co/index.php/ingenieria/article/download/17362/version/14852/14307/81681/0121-1129-rfing-33-67-e17362-e2.png"/>
						<label>(2)</label>
					</disp-formula>
				</p>
				<p>The general formula for analyzing the power flow of bipolar DC networks with a solidly grounded neutral wire and unbalanced loads can be obtained by adding an iterative counter to the demand voltage vector based on Tellegen’s second theorem <sup>[</sup><xref ref-type="bibr" rid="B25"><sup>25</sup></xref><sup>]</sup>. As the demand current vector is a function of the demand voltage vector, the formula for solving the power flow problem is as follows <sup>[</sup><xref ref-type="bibr" rid="B24"><sup>24</sup></xref><sup>]</sup>:</p>
				<p>
					<disp-formula id="e3">
						<graphic xlink:href="https://revistas.uptc.edu.co/index.php/ingenieria/article/download/17362/version/14852/14307/81682/0121-1129-rfing-33-67-e17362-e3.png"/>
						<label>(3)</label>
					</disp-formula>
				</p>
				<p>The iterative process of the successive approximations method ends when the difference between the voltage magnitudes of the current and previous iteration is lower than the pre-established error. This stopping criterion is defined in <xref ref-type="disp-formula" rid="e4">equation (4)</xref>.</p>
				<p>
					<disp-formula id="e4">
						<graphic xlink:href="https://revistas.uptc.edu.co/index.php/ingenieria/article/download/17362/version/14852/14307/81683/0121-1129-rfing-33-67-e17362-e4.png"/>
						<label>(4)</label>
					</disp-formula>
				</p>
				<p>where ɛ is the tolerance error. </p>
				<p>One of the great advantages of using <xref ref-type="disp-formula" rid="e3">equation (3)</xref> as an iterative formula is that the inverse of the matrix 𝐺 𝑑𝑑,𝑝𝑛 must only be calculated once, as it does not change throughout the process <sup>[</sup><xref ref-type="bibr" rid="B26"><sup>26</sup></xref><sup>]</sup>.</p>
				<p>The main difficulty when it comes to solving the power flow problem corresponds to the hyperbolic relationship between voltages and constant power loads <sup>[</sup><xref ref-type="bibr" rid="B27"><sup>27</sup></xref><sup>]</sup>. <xref ref-type="disp-formula" rid="e5">Equations (5)</xref> and <xref ref-type="disp-formula" rid="e6">(6)</xref> present the currents of the loads connected between the positive pole and the neutral wire, and those connected between the negative pole and the neutral wire, respectively.</p>
				<p>
					<disp-formula id="e5">
						<graphic xlink:href="https://revistas.uptc.edu.co/index.php/ingenieria/article/download/17362/version/14852/14307/81684/0121-1129-rfing-33-67-e17362-e5.png"/>
						<label>(5)</label>
					</disp-formula>
				</p>
				<p>
					<disp-formula id="e6">
						<graphic xlink:href="https://revistas.uptc.edu.co/index.php/ingenieria/article/download/17362/version/14852/14307/81685/0121-1129-rfing-33-67-e17362-e6.png"/>
						<label>(6)</label>
					</disp-formula>
				</p>
				<p>Where:</p>
				<p> 𝐼 𝑑𝑘,𝑝 𝑡 is the current demanded by the positive pole at node k.</p>
				<p> 𝐼 𝑑𝑘,𝑛 𝑡 is the current demanded by the negative pole at node k.</p>
				<p> 𝑃 𝑑𝑘,𝑝 is the power consumed at node k by the load connected to the positive pole.</p>
				<p> 𝑃 𝑑𝑘,𝑛 is the power consumed at node k by the load connected to the negative pole.</p>
				<p> 𝑉 𝑑𝑘,𝑝 𝑡 is the voltage level of the positive pole at node k.</p>
				<p> 𝑉 𝑑𝑘,𝑛 𝑡 is the voltage level of the negative pole at node k.</p>
				<p>Now, if the loads are connected between the positive and negative poles or vice versa, the currents are calculated as follows:</p>
				<p>
					<disp-formula id="e8">
						<graphic xlink:href="https://revistas.uptc.edu.co/index.php/ingenieria/article/download/17362/version/14852/14307/81686/0121-1129-rfing-33-67-e17362-e8.png"/>
						<label>(8)</label>
					</disp-formula>
				</p>
				<p>
					<disp-formula id="e9">
						<graphic xlink:href="https://revistas.uptc.edu.co/index.php/ingenieria/article/download/17362/version/14852/14307/81687/0121-1129-rfing-33-67-e17362-e9.png"/>
						<label>(9)</label>
					</disp-formula>
				</p>
				<p>Where:</p>
				<p> 𝑃 𝑑𝑘,𝑝𝑛 is the constant power load connected between the poles. </p>
			</sec>
			<sec>
				<title><italic>B. Extension to Systems that are not Solidly Grounded</italic></title>
				<p>When designing bipolar DC networks, especially low-voltage ones, there is the possibility that the neutral wire is not connected to the ground in all nodes. The only node that must be grounded is the network supply node <sup>[</sup><xref ref-type="bibr" rid="B11"><sup>11</sup></xref><sup>]</sup>, implying that the above-presented formulation requires considering said effect in the neutral conductor. To this effect, a new subscript is added to the nomenclature in <xref ref-type="disp-formula" rid="e3">equation (3)</xref>, indicating that the neutral wire is not solidly grounded, as shown below:</p>
				<p>
					<disp-formula id="e10">
						<graphic xlink:href="https://revistas.uptc.edu.co/index.php/ingenieria/article/download/17362/version/14852/14307/81688/0121-1129-rfing-33-67-e17362-e10.png"/>
						<label>(10)</label>
					</disp-formula>
				</p>
				<p>Where:</p>
				<p> 𝑉 𝑑,𝑝𝑜𝑛 𝑡+1 is the vector containing all the voltages of the demand nodes in the following order: positive, neutral, and negative. </p>
				<p> 𝐼 𝑑,𝑝𝑜𝑛 is the vector containing all the currents demanded in the positive and negative poles of the grid. </p>
				<p> 𝑉 𝑔,𝑝𝑜𝑛 is the vector containing all the voltage outputs of the generators in the following order: positive, neutral, and negative. </p>
				<p> 𝐺 𝑑𝑑,𝑝𝑜𝑛 is the component of the conductance matrix that relates the demand nodes, including the conductance of the neutral conductor. </p>
				<p> 𝐺 𝑑𝑔,𝑝𝑛 is the component of the conductance matrix that relates the slack and demand nodes, including the conductance of the neutral conductor. </p>
				<p>The most significant effect of including this in the power flow problem is related to the demand current. Therefore, if a load is connected between a pole and the neutral conductor, the demand currents are calculated as follows:</p>
				<p>
					<disp-formula id="e11">
						<graphic xlink:href="https://revistas.uptc.edu.co/index.php/ingenieria/article/download/17362/version/14852/14307/81689/0121-1129-rfing-33-67-e17362-e11.png"/>
						<label>(11)</label>
					</disp-formula>
				</p>
				<p>
					<disp-formula id="e12">
						<graphic xlink:href="https://revistas.uptc.edu.co/index.php/ingenieria/article/download/17362/version/14852/14307/81690/0121-1129-rfing-33-67-e17362-e12.png"/>
						<label>(12)</label>
					</disp-formula>
				</p>
				<p>
					<disp-formula id="e13">
						<graphic xlink:href="https://revistas.uptc.edu.co/index.php/ingenieria/article/download/17362/version/14852/14307/81691/0121-1129-rfing-33-67-e17362-e13.png"/>
						<label>(13)</label>
					</disp-formula>
				</p>
				<p>Where:</p>
				<p> 𝑃 𝑑𝑘,𝑝𝑜 is the constant power load connected between the positive pole and the neutral conductor. </p>
				<p> 𝑃 𝑑𝑘,𝑛𝑜 is the constant power load connected between the negative pole and the neutral conductor. </p>
				<p> 𝑉 𝑑𝑘,𝑜 𝑡 is the voltage of the neutral conductor at node k in iteration t. </p>
			</sec>
			<sec>
				<title><italic>C. Graphic Interface</italic></title>
				<p>This section presents the implementation of the graphic interface using the mathematical model shown in the previous section. This was done using the MATLAB 2021b software and the application development tool called AppDesigner. In the MATLAB environment, to access AppDesigner, the command appdesigner must be entered in the command window, as shown in <xref ref-type="fig" rid="f1">Figure 1</xref>.</p>
				<p>
					<fig id="f1">
						<label>Fig. 1</label>
						<caption>
							<title>Opening AppDesigner</title>
						</caption>
						<graphic xlink:href="https://revistas.uptc.edu.co/index.php/ingenieria/article/download/17362/version/14852/14307/81692/0121-1129-rfing-33-67-e17362-gf1.jpg"/>
					</fig>
				</p>
				<p>Next, the Blank app option is selected, which will open the workspace along with its design and code views, through which the graphic interface and the program code must be adjusted, respectively <sup>[</sup><xref ref-type="bibr" rid="B28"><sup>28</sup></xref><sup>]</sup>.</p>
				<p>The design view is divided into three windows: calculations, graphs, and system. The first of these includes the text editing boxes where the users will enter the program’s input data, as shown in <xref ref-type="fig" rid="f2">Figure 2</xref>.</p>
				<p>
					<fig id="f2">
						<label>Fig. 2</label>
						<caption>
							<title>Calculations window (part 1).</title>
						</caption>
						<graphic xlink:href="https://revistas.uptc.edu.co/index.php/ingenieria/article/download/17362/version/14852/14307/81693/0121-1129-rfing-33-67-e17362-gf2.jpg"/>
					</fig>
				</p>
				<p>For data with multiple inputs, the use of tables is advised, as this facilitates data capture and a better display for the user, which is why this paper uses two tables for entering the load and line data. To facilitate data entry, an option that allows entering information from an Excel file (.xlsx) was added. Two images were added (the logos of the university), as well as two text boxes, one to name the program and its authors and one to show the results after execution. Finally, a button was added to be pressed when all the input data were ready. <xref ref-type="fig" rid="f3">Figure 3</xref> shows all the above.</p>
				<p>
					<fig id="f3">
						<label>Fig. 3</label>
						<caption>
							<title>Calculations window (part 2)</title>
						</caption>
						<graphic xlink:href="https://revistas.uptc.edu.co/index.php/ingenieria/article/download/17362/version/14852/14307/81694/0121-1129-rfing-33-67-e17362-gf3.jpg"/>
					</fig>
				</p>
				<p>In the graphs window, an axis is added, which allows drawing the entered data on the Cartesian plane, as shown in <xref ref-type="fig" rid="f4">Figure 4</xref>. </p>
				<p>
					<fig id="f4">
						<label>Fig. 4</label>
						<caption>
							<title>Graphs window</title>
						</caption>
						<graphic xlink:href="https://revistas.uptc.edu.co/index.php/ingenieria/article/download/17362/version/14852/14307/81695/0121-1129-rfing-33-67-e17362-gf4.jpg"/>
					</fig>
				</p>
				<p>This window shows the voltage profiles at the end of the program’s execution. To the system window, an axis is also added, albeit without a ruler and with a transparent background. Thus, this axis does not look like a graph in the Cartesian plane. This window plots an approach to the system’s topology using graph theory <sup>[</sup><xref ref-type="bibr" rid="B29"><sup>29</sup></xref><sup>]</sup>.</p>
				<p>It is in the code view that all the entered data are captured. Here, the boxes and tables containing the data are named and stored in global variables for use anywhere in the code and at any time during execution.</p>
				<p>When pressing the aforementioned Calculate button, the code that calculates the power flow begins its execution. Once this process is complete, the app sends the results obtained to the text area, along with a graph showing the voltage profiles.</p>
				<p>After adjusting the functional part of the program, operation details are added in order to make the interface more user-friendly, e.g., the addition of colors for a better look, as shown in <xref ref-type="fig" rid="f5">Figure 5</xref>.</p>
				<p>
					<fig id="f5">
						<label>Fig. 5</label>
						<caption>
							<title>Final graphic interface</title>
						</caption>
						<graphic xlink:href="https://revistas.uptc.edu.co/index.php/ingenieria/article/download/17362/version/14852/14307/81696/0121-1129-rfing-33-67-e17362-gf5.jpg"/>
					</fig>
				</p>
			</sec>
		</sec>
		<sec sec-type="results|discussion">
			<title>III. Results and Discussion</title>
			<p>This section presents the test system considered in this work, the numerical validations carried out for its radial and meshed configurations, and an analysis and a discussion of the results obtained.</p>
			<sec>
				<title><italic>A. Test System</italic></title>
				<p>To demonstrate the effectiveness of this proposal and validate the data, a medium-voltage asymmetric bipolar DC distribution network was considered, which is composed of 21 nodes, 22 lines (meshed system), and 21 constant power loads. This feeder was originally used as a balanced network, as presented in <sup>[</sup><xref ref-type="bibr" rid="B23"><sup>23</sup></xref><sup>]</sup>. However, in this case, two lines are added, with the configuration shown in <xref ref-type="fig" rid="f6">Figure 6</xref>. Note that, in order to ensure open access to the work presented in this document, the developed tool can be downloaded at <ext-link ext-link-type="uri" xlink:href="https://mega.nz/folder/pc9UhA7I"><italic>Power flow for bipolar networks</italic></ext-link>.</p>
				<p>
					<fig id="f6">
						<label>Fig. 6</label>
						<caption>
							<title>Nodal connection scheme for the 21-node test feeder.</title>
						</caption>
						<graphic xlink:href="https://revistas.uptc.edu.co/index.php/ingenieria/article/download/17362/version/14852/14307/81697/0121-1129-rfing-33-67-e17362-gf6.png"/>
					</fig>
				</p>
				<p>The 21-node test system’s slack node operates at ±1000V. The rest of the electrical parameters can be found in <xref ref-type="table" rid="t1">Table 1</xref>.</p>
				<p>
					<table-wrap id="t1">
						<label>Table 1</label>
						<caption>
							<title>Electrical parameters of the 21-node test system.</title>
						</caption>
						<table>
							<colgroup>
								<col/>
								<col/>
								<col/>
								<col/>
								<col/>
								<col/>
							</colgroup>
							<tbody>
								<tr>
									<td align="center">𝑵𝒐𝒅𝒆𝒊 </td>
									<td align="center">𝑵𝒐𝒅𝒆𝒋 </td>
									<td align="center">𝑹𝒋𝒌 (Ω) </td>
									<td align="center">𝑷??𝒌,𝒑𝒐(𝒌𝑾) </td>
									<td align="center">𝑷𝒅𝒌,𝒏𝒐(𝒌𝑾) </td>
									<td align="center">𝑷𝒅𝒌,𝒑𝒏(𝒌𝑾) </td>
								</tr>
								<tr>
									<td align="center">1</td>
									<td align="center">2</td>
									<td align="center">0.053</td>
									<td align="center">70</td>
									<td align="center">100</td>
									<td align="center">0</td>
								</tr>
								<tr>
									<td align="center">1</td>
									<td align="center">3</td>
									<td align="center">0.054</td>
									<td align="center">0</td>
									<td align="center">0</td>
									<td align="center">0</td>
								</tr>
								<tr>
									<td align="center">3</td>
									<td align="center">4</td>
									<td align="center">0.054</td>
									<td align="center">36</td>
									<td align="center">40</td>
									<td align="center">120</td>
								</tr>
								<tr>
									<td align="center">4</td>
									<td align="center">5</td>
									<td align="center">0.063</td>
									<td align="center">4</td>
									<td align="center">0</td>
									<td align="center">0</td>
								</tr>
								<tr>
									<td align="center">4</td>
									<td align="center">6</td>
									<td align="center">0.051</td>
									<td align="center">36</td>
									<td align="center">0</td>
									<td align="center">0</td>
								</tr>
								<tr>
									<td align="center">3</td>
									<td align="center">7</td>
									<td align="center">0.037</td>
									<td align="center">0</td>
									<td align="center">0</td>
									<td align="center">0</td>
								</tr>
								<tr>
									<td align="center">7</td>
									<td align="center">8</td>
									<td align="center">0.079</td>
									<td align="center">32</td>
									<td align="center">50</td>
									<td align="center">0</td>
								</tr>
								<tr>
									<td align="center">7</td>
									<td align="center">9</td>
									<td align="center">0.072</td>
									<td align="center">80</td>
									<td align="center">0</td>
									<td align="center">100</td>
								</tr>
								<tr>
									<td align="center">3</td>
									<td align="center">10</td>
									<td align="center">0.053</td>
									<td align="center">0</td>
									<td align="center">10</td>
									<td align="center">0</td>
								</tr>
								<tr>
									<td align="center">10</td>
									<td align="center">11</td>
									<td align="center">0.038</td>
									<td align="center">45</td>
									<td align="center">30</td>
									<td align="center">0</td>
								</tr>
								<tr>
									<td align="center">11</td>
									<td align="center">12</td>
									<td align="center">0.079</td>
									<td align="center">68</td>
									<td align="center">70</td>
									<td align="center">0</td>
								</tr>
								<tr>
									<td align="center">11</td>
									<td align="center">13</td>
									<td align="center">0.078</td>
									<td align="center">10</td>
									<td align="center">0</td>
									<td align="center">75</td>
								</tr>
								<tr>
									<td align="center">10</td>
									<td align="center">14</td>
									<td align="center">0.083</td>
									<td align="center">0</td>
									<td align="center">0</td>
									<td align="center">0</td>
								</tr>
								<tr>
									<td align="center">14</td>
									<td align="center">15</td>
									<td align="center">0.065</td>
									<td align="center">22</td>
									<td align="center">30</td>
									<td align="center">0</td>
								</tr>
								<tr>
									<td align="center">15</td>
									<td align="center">16</td>
									<td align="center">0.064</td>
									<td align="center">23</td>
									<td align="center">10</td>
									<td align="center">0</td>
								</tr>
								<tr>
									<td align="center">16</td>
									<td align="center">17</td>
									<td align="center">0.074</td>
									<td align="center">43</td>
									<td align="center">0</td>
									<td align="center">60</td>
								</tr>
								<tr>
									<td align="center">16</td>
									<td align="center">18</td>
									<td align="center">0.081</td>
									<td align="center">34</td>
									<td align="center">60</td>
									<td align="center">0</td>
								</tr>
								<tr>
									<td align="center">14</td>
									<td align="center">19</td>
									<td align="center">0.078</td>
									<td align="center">9</td>
									<td align="center">15</td>
									<td align="center">0</td>
								</tr>
								<tr>
									<td align="center">19</td>
									<td align="center">20</td>
									<td align="center">0.084</td>
									<td align="center">21</td>
									<td align="center">10</td>
									<td align="center">50</td>
								</tr>
								<tr>
									<td align="center">19</td>
									<td align="center">21</td>
									<td align="center">0.082</td>
									<td align="center">21</td>
									<td align="center">20</td>
									<td align="center">0</td>
								</tr>
							</tbody>
						</table>
					</table-wrap>
				</p>
				<p>For the studied case, two scenarios are evaluated. In the first, the neutral wire is considered to be solidly grounded in all nodes, and in the second, it is considered to be floating.</p>
				<p>Two lines are added to the original study case. This information can be found in <xref ref-type="table" rid="t2">Table 2</xref>. One line goes from node 7 to node 9, and the other one is between nodes 11 and 16 to avoid exceeding a 5% regulation in all nodes. Not surpassing this limit is advisable, which is not possible without these two lines. This will be confirmed in the computational validation. </p>
				<p>
					<table-wrap id="t2">
						<label>Table 2</label>
						<caption>
							<title>Electrical parameters of the additional lines</title>
						</caption>
						<table>
							<colgroup>
								<col/>
								<col/>
								<col/>
							</colgroup>
							<tbody>
								<tr>
									<td align="center">𝑵𝒐𝒅𝒆𝒊 </td>
									<td align="center">𝑵𝒐𝒅𝒆𝒋 </td>
									<td align="center">𝑹𝒋𝒌 (Ω) </td>
								</tr>
								<tr>
									<td align="center">11</td>
									<td align="center">16</td>
									<td align="center">0.0370</td>
								</tr>
								<tr>
									<td align="center">7</td>
									<td align="center">19</td>
									<td align="center">0.0820</td>
								</tr>
							</tbody>
						</table>
					</table-wrap>
				</p>
			</sec>
			<sec>
				<title><italic>B. Numerical validations and discussion</italic></title>
				<p>Considering the above-presented system, the original one was simulated. The results are shown in <xref ref-type="table" rid="t3">Table 3</xref>. In these numerical results, it can be observed that, in the scenario with the neutral wire grounded in all nodes, some nodes exceed a 10% regulation in the positive pole, specifically nodes 16, 17, and 18. The node with the lowest voltage is no. 17, with a 10.99% regulation. Compared to its counterpart, the negative pole exhibits the lowest voltage at node 18, with a 9.14 regulation. This is due to the fact that the load is unbalanced. The total load reported for the positive pole is 554 kW, while that of the negative pole is 445 kW, which represents a difference of over 100 kW.</p>
				<p>
					<table-wrap id="t3">
						<label>Table 3</label>
						<caption>
							<title>Voltage for the two simulation cases in the original system</title>
						</caption>
						<table>
							<colgroup>
								<col/>
								<col/>
								<col/>
								<col/>
								<col/>
								<col/>
								<col/>
							</colgroup>
							<thead>
								<tr>
									<th align="center"> </th>
									<th align="center">Grounded neutral wire</th>
									<th align="center"> </th>
									<th align="center"> </th>
									<th align="center"> </th>
									<th align="center">Floating neutral wire</th>
									<th align="center"> </th>
								</tr>
								<tr>
									<th align="center">Node</th>
									<th align="center">Positive pole</th>
									<th align="center">Neutral wire</th>
									<th align="center">Negative pole</th>
									<th align="center">Positive pole</th>
									<th align="center">Neutral wire</th>
									<th align="center">Negative pole</th>
								</tr>
							</thead>
							<tbody>
								<tr>
									<td align="justify">1</td>
									<td align="justify">1000</td>
									<td align="justify">0</td>
									<td align="justify">-1000</td>
									<td align="justify">1000</td>
									<td align="justify">0</td>
									<td align="justify">-1000</td>
								</tr>
								<tr>
									<td align="justify">2</td>
									<td align="justify">996.2761</td>
									<td align="justify">0</td>
									<td align="justify">-994.6716</td>
									<td align="justify">996.2822</td>
									<td align="justify">-1.6193</td>
									<td align="justify">-994.6629</td>
								</tr>
								<tr>
									<td align="justify">3</td>
									<td align="justify">960.0684</td>
									<td align="justify">0</td>
									<td align="justify">-968.4101</td>
									<td align="justify">959.5206</td>
									<td align="justify">9.2158</td>
									<td align="justify">-968.7363</td>
								</tr>
								<tr>
									<td align="justify">4</td>
									<td align="justify">952.3714</td>
									<td align="justify">0</td>
									<td align="justify">-962.7830</td>
									<td align="justify">951.7636</td>
									<td align="justify">11.3722</td>
									<td align="justify">-963.1359</td>
								</tr>
								<tr>
									<td align="justify">5</td>
									<td align="justify">952.1067</td>
									<td align="justify">0</td>
									<td align="justify">-962.7830</td>
									<td align="justify">951.4955</td>
									<td align="justify">11.6403</td>
									<td align="justify">-963.1359</td>
								</tr>
								<tr>
									<td align="justify">6</td>
									<td align="justify">950.4397</td>
									<td align="justify">0</td>
									<td align="justify">-962.7830</td>
									<td align="justify">949.8031</td>
									<td align="justify">13.3328</td>
									<td align="justify">-963.1359</td>
								</tr>
								<tr>
									<td align="justify">7</td>
									<td align="justify">953.7448</td>
									<td align="justify">0</td>
									<td align="justify">-964.5412</td>
									<td align="justify">953.1184</td>
									<td align="justify">11.7701</td>
									<td align="justify">-964.8885</td>
								</tr>
								<tr>
									<td align="justify">8</td>
									<td align="justify">951.0868</td>
									<td align="justify">0</td>
									<td align="justify">-960.4285</td>
									<td align="justify">950.4291</td>
									<td align="justify">10.3923</td>
									<td align="justify">-960.8214</td>
								</tr>
								<tr>
									<td align="justify">9</td>
									<td align="justify">943.8619</td>
									<td align="justify">0</td>
									<td align="justify">-960.7609</td>
									<td align="justify">943.1110</td>
									<td align="justify">17.9963</td>
									<td align="justify">-961.1074</td>
								</tr>
								<tr>
									<td align="justify">10</td>
									<td align="justify">937.4888</td>
									<td align="justify">0</td>
									<td align="justify">-948.4699</td>
									<td align="justify">936.5747</td>
									<td align="justify">12.4856</td>
									<td align="justify">-949.0603</td>
								</tr>
								<tr>
									<td align="justify">11</td>
									<td align="justify">930.9221</td>
									<td align="justify">0</td>
									<td align="justify">-942.8952</td>
									<td align="justify">929.9260</td>
									<td align="justify">13.6205</td>
									<td align="justify">-943.5464</td>
								</tr>
								<tr>
									<td align="justify">12</td>
									<td align="justify">925.1152</td>
									<td align="justify">0</td>
									<td align="justify">-936.9933</td>
									<td align="justify">924.0247</td>
									<td align="justify">13.7095</td>
									<td align="justify">-937.7342</td>
								</tr>
								<tr>
									<td align="justify">13</td>
									<td align="justify">926.9467</td>
									<td align="justify">0</td>
									<td align="justify">-939.7613</td>
									<td align="justify">925.9357</td>
									<td align="justify">14.4763</td>
									<td align="justify">-940.4120</td>
								</tr>
								<tr>
									<td align="justify">14</td>
									<td align="justify">916.4716</td>
									<td align="justify">0</td>
									<td align="justify">-930.2941</td>
									<td align="justify">915.1628</td>
									<td align="justify">15.9905</td>
									<td align="justify">-931.1533</td>
								</tr>
								<tr>
									<td align="justify">15</td>
									<td align="justify">905.4445</td>
									<td align="justify">0</td>
									<td align="justify">-921.0086</td>
									<td align="justify">903.9041</td>
									<td align="justify">18.1140</td>
									<td align="justify">-922.0181</td>
								</tr>
								<tr>
									<td align="justify">16</td>
									<td align="justify">896.1421</td>
									<td align="justify">0</td>
									<td align="justify">-913.9506</td>
									<td align="justify">894.4081</td>
									<td align="justify">20.6576</td>
									<td align="justify">-915.0657</td>
								</tr>
								<tr>
									<td align="justify">17</td>
									<td align="justify">890.1027</td>
									<td align="justify">0</td>
									<td align="justify">-911.4861</td>
									<td align="justify">888.2594</td>
									<td align="justify">24.3408</td>
									<td align="justify">-912.6002</td>
								</tr>
								<tr>
									<td align="justify">18</td>
									<td align="justify">893.0583</td>
									<td align="justify">0</td>
									<td align="justify">-908.6017</td>
									<td align="justify">891.2523</td>
									<td align="justify">18.5787</td>
									<td align="justify">-909.8310</td>
								</tr>
								<tr>
									<td align="justify">19</td>
									<td align="justify">909.9529</td>
									<td align="justify">0</td>
									<td align="justify">-924.3558</td>
									<td align="justify">908.5513</td>
									<td align="justify">16.7360</td>
									<td align="justify">-925.2873</td>
								</tr>
								<tr>
									<td align="justify">20</td>
									<td align="justify">905.7062</td>
									<td align="justify">0</td>
									<td align="justify">-921.1449</td>
									<td align="justify">904.2616</td>
									<td align="justify">17.8323</td>
									<td align="justify">-922.0939</td>
								</tr>
								<tr>
									<td align="justify">21</td>
									<td align="justify">908.0565</td>
									<td align="justify">0</td>
									<td align="justify">-922.5782</td>
									<td align="justify">906.6158</td>
									<td align="justify">16.9277</td>
									<td align="justify">-923.5435</td>
								</tr>
							</tbody>
						</table>
					</table-wrap>
				</p>
				<p>In the simulation where the neutral wire is only grounded at the slack node, it is observed that the neutral conductor of nodes 16 and 17 exceeds 20 V in magnitude, which may have negative consequences for the sensitivity of some devices. It should also be emphasized that voltage regulation slightly decreases compared to the previous case, but this is not a significant fact.</p>
				<p>To demonstrate the effectiveness of the application for solving the power flow of unbalanced bipolar DC networks, we included a scenario with two additional lines (<xref ref-type="table" rid="t2">Table 2</xref>), aiming to reduce voltage regulation at critical nodes and use a meshed network to confirm that our approach works with both topologies. </p>
				<p>
					<xref ref-type="table" rid="t4">Table 4</xref> shows the results of the new simulation case. Accordingly, it can be stated that the power losses for the solidly grounded scenario is 75.1832 kW, 3.5540 kW less than those of the case with the floating neutral wire. This is associated with the currents flowing through the neutral wire, as a result of load imbalances between the positive and negative poles.</p>
				<p>
					<table-wrap id="t4">
						<label>Table 4</label>
						<caption>
							<title>Voltage for the two simulation cases in the modified system</title>
						</caption>
						<table>
							<colgroup>
								<col/>
								<col/>
								<col/>
								<col/>
								<col/>
								<col/>
								<col/>
							</colgroup>
							<thead>
								<tr>
									<th align="center"> </th>
									<th align="center">Grounded neutral wire</th>
									<th align="center"> </th>
									<th align="center"> </th>
									<th align="center"> </th>
									<th align="center">Floating neutral wire</th>
									<th align="center"> </th>
								</tr>
								<tr>
									<th align="center">Node</th>
									<th align="center">Positive pole</th>
									<th align="center">Neutral wire</th>
									<th align="center">Negative pole</th>
									<th align="center">Positive pole</th>
									<th align="center">Neutral wire</th>
									<th align="center">Negative pole</th>
								</tr>
							</thead>
							<tbody>
								<tr>
									<td align="justify">1</td>
									<td align="justify">1000</td>
									<td align="justify">0</td>
									<td align="justify">1000</td>
									<td align="justify">1000</td>
									<td align="justify">0</td>
									<td align="justify">1000</td>
								</tr>
								<tr>
									<td align="justify">2</td>
									<td align="justify">996.2761</td>
									<td align="justify">0.0000</td>
									<td align="justify">994.6716</td>
									<td align="justify">996.2822</td>
									<td align="justify">-1.6193</td>
									<td align="justify">994.6629</td>
								</tr>
								<tr>
									<td align="justify">3</td>
									<td align="justify">960.5554</td>
									<td align="justify">0.0000</td>
									<td align="justify">968.7957</td>
									<td align="justify">960.1064</td>
									<td align="justify">8.9492</td>
									<td align="justify">969.0556</td>
								</tr>
								<tr>
									<td align="justify">4</td>
									<td align="justify">952.8622</td>
									<td align="justify">0.0000</td>
									<td align="justify">963.1711</td>
									<td align="justify">952.3551</td>
									<td align="justify">11.1017</td>
									<td align="justify">963.4568</td>
								</tr>
								<tr>
									<td align="justify">5</td>
									<td align="justify">952.5976</td>
									<td align="justify">0.0000</td>
									<td align="justify">963.1711</td>
									<td align="justify">952.0872</td>
									<td align="justify">11.3696</td>
									<td align="justify">963.4568</td>
								</tr>
								<tr>
									<td align="justify">6</td>
									<td align="justify">950.9314</td>
									<td align="justify">0.0000</td>
									<td align="justify">963.1711</td>
									<td align="justify">950.3963</td>
									<td align="justify">13.0605</td>
									<td align="justify">963.4568</td>
								</tr>
								<tr>
									<td align="justify">7</td>
									<td align="justify">950.2970</td>
									<td align="justify">0.0000</td>
									<td align="justify">961.2054</td>
									<td align="justify">949.7234</td>
									<td align="justify">11.8017</td>
									<td align="justify">961.5251</td>
								</tr>
								<tr>
									<td align="justify">8</td>
									<td align="justify">947.6292</td>
									<td align="justify">0.0000</td>
									<td align="justify">957.0782</td>
									<td align="justify">947.0243</td>
									<td align="justify">10.4196</td>
									<td align="justify">957.4439</td>
								</tr>
								<tr>
									<td align="justify">9</td>
									<td align="justify">940.3779</td>
									<td align="justify">0.0000</td>
									<td align="justify">957.4115</td>
									<td align="justify">939.6789</td>
									<td align="justify">18.0515</td>
									<td align="justify">957.7304</td>
								</tr>
								<tr>
									<td align="justify">10</td>
									<td align="justify">944.0865</td>
									<td align="justify">0.0000</td>
									<td align="justify">954.5621</td>
									<td align="justify">943.4321</td>
									<td align="justify">11.5340</td>
									<td align="justify">954.9661</td>
								</tr>
								<tr>
									<td align="justify">11</td>
									<td align="justify">934.2946</td>
									<td align="justify">0.0000</td>
									<td align="justify">946.4192</td>
									<td align="justify">933.5170</td>
									<td align="justify">13.3896</td>
									<td align="justify">946.9066</td>
								</tr>
								<tr>
									<td align="justify">12</td>
									<td align="justify">928.5089</td>
									<td align="justify">0.0000</td>
									<td align="justify">940.5396</td>
									<td align="justify">927.6406</td>
									<td align="justify">13.4729</td>
									<td align="justify">941.1135</td>
								</tr>
								<tr>
									<td align="justify">13</td>
									<td align="justify">930.3339</td>
									<td align="justify">0.0000</td>
									<td align="justify">943.2969</td>
									<td align="justify">929.5420</td>
									<td align="justify">14.2418</td>
									<td align="justify">943.7838</td>
								</tr>
								<tr>
									<td align="justify">14</td>
									<td align="justify">939.6834</td>
									<td align="justify">0.0000</td>
									<td align="justify">950.9273</td>
									<td align="justify">938.9764</td>
									<td align="justify">12.3878</td>
									<td align="justify">951.3641</td>
								</tr>
								<tr>
									<td align="justify">15</td>
									<td align="justify">934.6149</td>
									<td align="justify">0.0000</td>
									<td align="justify">946.3633</td>
									<td align="justify">933.8392</td>
									<td align="justify">13.0128</td>
									<td align="justify">946.8520</td>
								</tr>
								<tr>
									<td align="justify">16</td>
									<td align="justify">931.1309</td>
									<td align="justify">0.0000</td>
									<td align="justify">943.8982</td>
									<td align="justify">930.3101</td>
									<td align="justify">14.0995</td>
									<td align="justify">944.4095</td>
								</tr>
								<tr>
									<td align="justify">17</td>
									<td align="justify">925.3137</td>
									<td align="justify">0.0000</td>
									<td align="justify">941.5199</td>
									<td align="justify">924.4222</td>
									<td align="justify">17.6084</td>
									<td align="justify">942.0307</td>
								</tr>
								<tr>
									<td align="justify">18</td>
									<td align="justify">928.1637</td>
									<td align="justify">0.0000</td>
									<td align="justify">938.7210</td>
									<td align="justify">927.3012</td>
									<td align="justify">11.9995</td>
									<td align="justify">939.3007</td>
								</tr>
								<tr>
									<td align="justify">19</td>
									<td align="justify">941.6278</td>
									<td align="justify">0.0000</td>
									<td align="justify">952.9884</td>
									<td align="justify">940.9537</td>
									<td align="justify">12.4401</td>
									<td align="justify">953.3937</td>
								</tr>
								<tr>
									<td align="justify">20</td>
									<td align="justify">937.5209</td>
									<td align="justify">0.0000</td>
									<td align="justify">949.8788</td>
									<td align="justify">936.8176</td>
									<td align="justify">13.4789</td>
									<td align="justify">950.2965</td>
								</tr>
								<tr>
									<td align="justify">21</td>
									<td align="justify">939.7955</td>
									<td align="justify">0.0000</td>
									<td align="justify">951.2644</td>
									<td align="justify">939.0951</td>
									<td align="justify">12.5979</td>
									<td align="justify">951.6930</td>
								</tr>
							</tbody>
						</table>
					</table-wrap>
				</p>
				<p>On the other hand, voltage regulation decreases significantly with respect to the original system, i.e., from 10.99% in the radial network to 7.47% in the meshed one. In the positive pole, the voltage goes from 890.1027 V to 925.313 V. This may be due to the fact that adding lines changed the current distribution, and the most remote nodes do not perceive such a drastic voltage difference.</p>
				<p>
					<xref ref-type="fig" rid="f7">Figure 7</xref> shows the voltage profiles for the modified study case with the solidly grounded neutral wire, and <xref ref-type="fig" rid="f8">Figure 8</xref> presents the voltage profile for the modified scenario with the floating neutral conductor. </p>
				<p>
					<fig id="f7">
						<label>Fig. 7</label>
						<caption>
							<title>Voltage profiles for the modified study case (solidly grounded neutral wire).</title>
						</caption>
						<graphic xlink:href="https://revistas.uptc.edu.co/index.php/ingenieria/article/download/17362/version/14852/14307/81698/0121-1129-rfing-33-67-e17362-gf7.jpg"/>
					</fig>
				</p>
				<p>
					<fig id="f8">
						<label>Fig. 8</label>
						<caption>
							<title>Voltage profiles for the modified study case (floating neutral wire)</title>
						</caption>
						<graphic xlink:href="https://revistas.uptc.edu.co/index.php/ingenieria/article/download/17362/version/14852/14307/81699/0121-1129-rfing-33-67-e17362-gf8.jpg"/>
					</fig>
				</p>
			</sec>
		</sec>
		<sec sec-type="conclusions">
			<title>V. Conclusions</title>
			<p>This work analyzed solidly grounded and non-grounded bipolar DC networks, to which the same successive approximations method was applied, demonstrating its effectiveness in both cases. In addition, this method can be used in both radial and meshed grids. The implementation of a graphic interface facilitates its use; as it is user-friendly, this interface can be used by anyone with basic knowledge of the subject.</p>
			<p>A graphical analysis of voltage profiles allows quickly determining key factors in a bipolar DC network, such as the system’s electrical center (i.e., the node with the highest voltage), the nodes in which the highest load is concentrated, and, in some cases and with the help of a system topology scheme, the lines with the greatest losses.</p>
			<p>As possible research works, the following could be conducted in the future: (i) implementing new power flow methods for bipolar grids based on Taylor approximations and the triangular method; (ii) studying the phase balancing problem by combining the successive approximations method and a metaheuristic algorithm of a binary nature; and (iii) proposing a convex reformulation to study the optimal power flow problem in bipolar networks with a high penetration of distributed energy resources.</p>
		</sec>
	</body>
	<back>
		<ack>
			<title>Acknowledgments</title>
			<p>This research work was carried out within the framework of the academic production graduation modality to obtain the degree of Electrical Engineer from the curricular project in Electrical Engineering of Universidad Distrital Francisco José de Caldas.</p>
		</ack>
		<ref-list>
			<title>References</title>
			<ref id="B1">
				<label>[1]</label>
				<mixed-citation>[1] M. I. MuhammadRidzuan, N. F. Mohd Fauzi, N. N. R. Roslan, N. Mohd Saad, &quot;Urban and rural medium voltage networks reliability assessment,&quot; SN Applied Sciences, vol. 2, 2020. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1007/s42452-019-1612-z">https://doi.org/10.1007/s42452-019-1612-z</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>MuhammadRidzuan</surname>
							<given-names>M. I.</given-names>
						</name>
						<name>
							<surname>Fauzi</surname>
							<given-names>N. F. Mohd</given-names>
						</name>
						<name>
							<surname>Roslan</surname>
							<given-names>N. N. R.</given-names>
						</name>
						<name>
							<surname>Mohd Saad</surname>
							<given-names>N.</given-names>
						</name>
					</person-group>
					<article-title>Urban and rural medium voltage networks reliability assessment</article-title>
					<source>SN Applied Sciences</source>
					<volume>2</volume>
					<year>2020</year>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1007/s42452-019-1612-z">https://doi.org/10.1007/s42452-019-1612-z</ext-link>
				</element-citation>
			</ref>
			<ref id="B2">
				<label>[2]</label>
				<mixed-citation>[2] M. Lavorato, J. F. Franco, M. J. Rider, R. Romero, &quot;Imposing Radiality Constraints in Distribution System Optimization Problems,&quot; IEEE Transactions on Power Systems, vol. 27, pp. 172-180, 2012. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1109/tpwrs.2011.2161349">https://doi.org/10.1109/tpwrs.2011.2161349</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Lavorato</surname>
							<given-names>M.</given-names>
						</name>J. F. Franco<name>
							<surname>Rider</surname>
							<given-names>M. J.</given-names>
						</name>
						<name>
							<surname>Romero</surname>
							<given-names>R.</given-names>
						</name>
					</person-group>
					<article-title>Imposing Radiality Constraints in Distribution System Optimization Problems</article-title>
					<source>IEEE Transactions on Power Systems</source>
					<volume>27</volume>
					<fpage>172</fpage>
					<lpage>180</lpage>
					<year>2012</year>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1109/tpwrs.2011.2161349">https://doi.org/10.1109/tpwrs.2011.2161349</ext-link>
				</element-citation>
			</ref>
			<ref id="B3">
				<label>[3]</label>
				<mixed-citation>[3] J. A. Melo Rodriguez, C. A. Cortés Guerrero, &quot;Análisis de vulnerabilidad de sistemas de potencia incluyendo incertidumbre en las variables con lógica difusa tipo 2,&quot; Revista Tecnura, vol. 20, no. 49, pp. 100-119, 2016. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.14483/udistrital.jour.tecnura.2016.3.a07">https://doi.org/10.14483/udistrital.jour.tecnura.2016.3.a07</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Melo Rodriguez</surname>
							<given-names>J. A.</given-names>
						</name>
						<name>
							<surname>Cortés Guerrero</surname>
							<given-names>C. A.</given-names>
						</name>
					</person-group>
					<article-title>Análisis de vulnerabilidad de sistemas de potencia incluyendo incertidumbre en las variables con lógica difusa tipo 2</article-title>
					<source>Revista Tecnura</source>
					<volume>20</volume>
					<issue>49</issue>
					<fpage>100</fpage>
					<lpage>119</lpage>
					<year>2016</year>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.14483/udistrital.jour.tecnura.2016.3.a07">https://doi.org/10.14483/udistrital.jour.tecnura.2016.3.a07</ext-link>
				</element-citation>
			</ref>
			<ref id="B4">
				<label>[4]</label>
				<mixed-citation>[4] P. Siano, G. Rigatos, A. Piccolo, &quot;Active Distribution Networks and Smart Grids: Optimal Allocation of Wind Turbines by Using Hybrid GA and Multi-Period OPF,&quot; in Computational Intelligence Systems in Industrial Engineering, Atlantis Press, 2012, pp. 579-599. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.2991/978-94-91216-77-0_27">https://doi.org/10.2991/978-94-91216-77-0_27</ext-link>
				</mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<name>
							<surname>Siano</surname>
							<given-names>P.</given-names>
						</name>
						<name>
							<surname>Rigatos</surname>
							<given-names>G.</given-names>
						</name>
						<name>
							<surname>Piccolo</surname>
							<given-names>A.</given-names>
						</name>
					</person-group>
					<chapter-title>Distribution Networks and Smart Grids: Optimal Allocation of Wind Turbines by Using Hybrid GA and Multi-Period OPF</chapter-title>
					<source>Computational Intelligence Systems in Industrial Engineering</source>
					<publisher-name>Atlantis Press</publisher-name>
					<year>2012</year>
					<fpage>579</fpage>
					<lpage>599</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.2991/978-94-91216-77-0_27">https://doi.org/10.2991/978-94-91216-77-0_27</ext-link>
				</element-citation>
			</ref>
			<ref id="B5">
				<label>[5]</label>
				<mixed-citation>[5] A. Garces, &quot;Uniqueness of the power flow solutions in low voltage direct current grids,&quot; Electric Power Systems Research, vol. 151, pp. 149-153, 2017. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.epsr.2017.05.031">https://doi.org/10.1016/j.epsr.2017.05.031</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Garces</surname>
							<given-names>A.</given-names>
						</name>
					</person-group>
					<article-title>Uniqueness of the power flow solutions in low voltage direct current grids</article-title>
					<source>Electric Power Systems Research</source>
					<volume>151</volume>
					<fpage>149</fpage>
					<lpage>153</lpage>
					<year>2017</year>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.epsr.2017.05.031">https://doi.org/10.1016/j.epsr.2017.05.031</ext-link>
				</element-citation>
			</ref>
			<ref id="B6">
				<label>[6]</label>
				<mixed-citation>[6] L. Z. Lu Zhang, W. T. Wei Tang, J. L. Jun Liang, G. L. Gen Li, Y. C. Yongxiang Cai, T. Y. Tao Yan, &quot;A medium voltage hybrid AC/DC distribution network and its economic evaluation,&quot; in 12th IET International Conference on AC and DC Power Transmission, 2016. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1049/cp.2016.0446">https://doi.org/10.1049/cp.2016.0446</ext-link>
				</mixed-citation>
				<element-citation publication-type="confproc">
					<person-group person-group-type="author">
						<name>
							<surname>Lu Zhang</surname>
							<given-names>L. Z.</given-names>
						</name>
						<name>
							<surname>Wei Tang</surname>
							<given-names>W. T.</given-names>
						</name>
						<name>
							<surname>Jun Liang</surname>
							<given-names>J. L.</given-names>
						</name>
						<name>
							<surname>Gen Li</surname>
							<given-names>G. L.</given-names>
						</name>
						<name>
							<surname>Yongxiang Cai</surname>
							<given-names>Y. C.</given-names>
						</name>
						<name>
							<surname>Tao Yan</surname>
							<given-names>T. Y.</given-names>
						</name>
					</person-group>
					<source>A medium voltage hybrid AC/DC distribution network and its economic evaluation</source>
					<conf-name>12IET International Conference on AC and DC Power Transmission</conf-name>
					<year>2016</year>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1049/cp.2016.0446">https://doi.org/10.1049/cp.2016.0446</ext-link>
				</element-citation>
			</ref>
			<ref id="B7">
				<label>[7]</label>
				<mixed-citation>[7] L. F. Grisales-Noreña, O. D. Montoya, W. J. Gil-González, A.-J. Perea-Moreno, M.-A. Perea-Moreno, &quot;A Comparative Study on Power Flow Methods for Direct-Current Networks Considering Processing Time and Numerical Convergence Errors,&quot; Electronics, vol. 9, e2062, 2020. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.3390/electronics9122062">https://doi.org/10.3390/electronics9122062</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Grisales-Noreña</surname>
							<given-names>L. F.</given-names>
						</name>
						<name>
							<surname>Montoya</surname>
							<given-names>O. D.</given-names>
						</name>
						<name>
							<surname>Gil-González</surname>
							<given-names>W. J.</given-names>
						</name>
						<name>
							<surname>Perea-Moreno</surname>
							<given-names>A.-J.</given-names>
						</name>
						<name>
							<surname>Perea-Moreno</surname>
							<given-names>M.-A.</given-names>
						</name>
					</person-group>
					<article-title>A Comparative Study on Power Flow Methods for Direct-Current Networks Considering Processing Time and Numerical Convergence Errors</article-title>
					<source>Electronics</source>
					<volume>9</volume>
					<size units="pages">e2062</size>
					<year>2020</year>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.3390/electronics9122062">https://doi.org/10.3390/electronics9122062</ext-link>
				</element-citation>
			</ref>
			<ref id="B8">
				<label>[8]</label>
				<mixed-citation>[8] O. D. Montoya Giraldo, A. Arias-Londoño, A. Molina-Cabrera, &quot;Branch Optimal Power Flow Model for DC Networks with Radial Structure: A Conic Relaxation,&quot; Tecnura, vol. 26, pp. 30-42, 2022. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.14483/22487638.18635">https://doi.org/10.14483/22487638.18635</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Montoya Giraldo</surname>
							<given-names>O. D.</given-names>
						</name>
						<name>
							<surname>Arias-Londoño</surname>
							<given-names>A.</given-names>
						</name>
						<name>
							<surname>Molina-Cabrera</surname>
							<given-names>A.</given-names>
						</name>
					</person-group>
					<article-title>Branch Optimal Power Flow Model for DC Networks with Radial Structure: A Conic Relaxation</article-title>
					<source>Tecnura</source>
					<volume>26</volume>
					<fpage>30</fpage>
					<lpage>42</lpage>
					<year>2022</year>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.14483/22487638.18635">https://doi.org/10.14483/22487638.18635</ext-link>
				</element-citation>
			</ref>
			<ref id="B9">
				<label>[9]</label>
				<mixed-citation>[9] W. Gil-González, O. D. Montoya, C. Restrepo, J. C. Hernández, &quot;Sensorless Adaptive Voltage Control for Classical DC-DC Converters Feeding Unknown Loads: A Generalized PI Passivity-Based Approach,&quot; Sensors, vol. 21, e6367, 2021. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.3390/s21196367">https://doi.org/10.3390/s21196367</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Gil-González</surname>
							<given-names>W.</given-names>
						</name>
						<name>
							<surname>Montoya</surname>
							<given-names>O. D.</given-names>
						</name>
						<name>
							<surname>Restrepo</surname>
							<given-names>C.</given-names>
						</name>
						<name>
							<surname>Hernández</surname>
							<given-names>J. C.</given-names>
						</name>
					</person-group>
					<article-title>Sensorless Adaptive Voltage Control for Classical DC-DC Converters Feeding Unknown Loads: A Generalized PI Passivity-Based Approach</article-title>
					<source>Sensors</source>
					<volume>21</volume>
					<size units="pages">e6367</size>
					<year>2021</year>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.3390/s21196367">https://doi.org/10.3390/s21196367</ext-link>
				</element-citation>
			</ref>
			<ref id="B10">
				<label>[10]</label>
				<mixed-citation>[10] V. Monteiro, L. F. C. Monteiro, F. L. Franco, R. Mandrioli, M. Ricco, G. Grandi, J. L. Afonso, &quot;The Role of Front-End AC/DC Converters in Hybrid AC/DC Smart Homes: Analysis and Experimental Validation,&quot; Electronics, vol. 10, e2601, 2021. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.3390/electronics10212601">https://doi.org/10.3390/electronics10212601</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Monteiro</surname>
							<given-names>V.</given-names>
						</name>
						<name>
							<surname>Monteiro</surname>
							<given-names>L. F. C.</given-names>
						</name>
						<name>
							<surname>Franco</surname>
							<given-names>F. L.</given-names>
						</name>
						<name>
							<surname>Mandrioli</surname>
							<given-names>R.</given-names>
						</name>
						<name>
							<surname>Ricco</surname>
							<given-names>M.</given-names>
						</name>
						<name>
							<surname>Grandi</surname>
							<given-names>G.</given-names>
						</name>
						<name>
							<surname>Afonso</surname>
							<given-names>J. L.</given-names>
						</name>
					</person-group>
					<article-title>The Role of Front-End AC/DC Converters in Hybrid AC/DC Smart Homes: Analysis and Experimental Validation</article-title>
					<source>Electronics</source>
					<volume>10</volume>
					<size units="pages">e2601</size>
					<year>2021</year>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.3390/electronics10212601">https://doi.org/10.3390/electronics10212601</ext-link>
				</element-citation>
			</ref>
			<ref id="B11">
				<label>[11]</label>
				<mixed-citation>[11] B. S. Chew, Y. Xu, Q. Wu, &quot;Voltage Balancing for Bipolar DC Distribution Grids: A Power Flow Based Binary Integer Multi-Objective Optimization Approach,&quot; IEEE Transactions on Power Systems, vol. 34, pp. 28-39, 2019. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1109/tpwrs.2018.2866817">https://doi.org/10.1109/tpwrs.2018.2866817</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Chew</surname>
							<given-names>B. S.</given-names>
						</name>
						<name>
							<surname>Xu</surname>
							<given-names>Y.</given-names>
						</name>
						<name>
							<surname>Wu</surname>
							<given-names>Q.</given-names>
						</name>
					</person-group>
					<article-title>Voltage Balancing for Bipolar DC Distribution Grids: A Power Flow Based Binary Integer Multi-Objective Optimization Approach</article-title>
					<source>IEEE Transactions on Power Systems</source>
					<volume>34</volume>
					<fpage>28</fpage>
					<lpage>39</lpage>
					<year>2019</year>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1109/tpwrs.2018.2866817">https://doi.org/10.1109/tpwrs.2018.2866817</ext-link>
				</element-citation>
			</ref>
			<ref id="B12">
				<label>[12]</label>
				<mixed-citation>[12] G. Van den Broeck, S. De Breucker, J. Beerten, J. Zwysen, M. Dalla Vecchia, J. Driesen, &quot;Analysis of three-level converters with voltage balancing capability in bipolar DC distribution networks,&quot; in IEEE Second International Conference on DC Microgrids (ICDCM), 2017. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1109/icdcm.2017.8001052">https://doi.org/10.1109/icdcm.2017.8001052</ext-link>
				</mixed-citation>
				<element-citation publication-type="confproc">
					<person-group person-group-type="author">
						<name>
							<surname>Van den Broeck</surname>
							<given-names>G.</given-names>
						</name>
						<name>
							<surname>Breucker</surname>
							<given-names>S. De</given-names>
						</name>
						<name>
							<surname>Beerten</surname>
							<given-names>J.</given-names>
						</name>
						<name>
							<surname>Zwysen</surname>
							<given-names>J.</given-names>
						</name>
						<name>
							<surname>Vecchia</surname>
							<given-names>M. Dalla</given-names>
						</name>
						<name>
							<surname>Driesen</surname>
							<given-names>J.</given-names>
						</name>
					</person-group>
					<source>Analysis of three-level converters with voltage balancing capability in bipolar DC distribution networks</source>
					<conf-name>IEEE Second International Conference on DC Microgrids (ICDCM)</conf-name>
					<year>2017</year>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1109/icdcm.2017.8001052">https://doi.org/10.1109/icdcm.2017.8001052</ext-link>
				</element-citation>
			</ref>
			<ref id="B13">
				<label>[13]</label>
				<mixed-citation>[13] A. Garcés, O.-D. Montoya, &quot;A Potential Function for the Power Flow in DC Microgrids: An Analysis of the Uniqueness and Existence of the Solution and Convergence of the Algorithms,&quot; Journal of Control, Automation and Electrical Systems, vol. 30, pp. 794-801, 2019. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1007/s40313-019-00489-4">https://doi.org/10.1007/s40313-019-00489-4</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Garcés</surname>
							<given-names>A.</given-names>
						</name>
						<name>
							<surname>Montoya</surname>
							<given-names>O.-D.</given-names>
						</name>
					</person-group>
					<article-title>A Potential Function for the Power Flow in DC Microgrids: An Analysis of the Uniqueness and Existence of the Solution and Convergence of the Algorithms</article-title>
					<source>Journal of Control, Automation and Electrical Systems</source>
					<volume>30</volume>
					<fpage>794</fpage>
					<lpage>801</lpage>
					<year>2019</year>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1007/s40313-019-00489-4">https://doi.org/10.1007/s40313-019-00489-4</ext-link>
				</element-citation>
			</ref>
			<ref id="B14">
				<label>[14]</label>
				<mixed-citation>[14] L. Mackay, R. Guarnotta, A. Dimou, G. Morales-Espana, L. Ramirez-Elizondo, P. Bauer, &quot;Optimal Power Flow for Unbalanced Bipolar DC Distribution Grids,&quot; IEEE Access, vol. 6, pp. 5199-5207, 2018. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1109/access.2018.2789522">https://doi.org/10.1109/access.2018.2789522</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Mackay</surname>
							<given-names>L.</given-names>
						</name>
						<name>
							<surname>Guarnotta</surname>
							<given-names>R.</given-names>
						</name>
						<name>
							<surname>Dimou</surname>
							<given-names>A.</given-names>
						</name>
						<name>
							<surname>Morales-Espana</surname>
							<given-names>G.</given-names>
						</name>
						<name>
							<surname>Ramirez-Elizondo</surname>
							<given-names>L.</given-names>
						</name>
						<name>
							<surname>Bauer</surname>
							<given-names>P.</given-names>
						</name>
					</person-group>
					<article-title>Optimal Power Flow for Unbalanced Bipolar DC Distribution Grids</article-title>
					<source>IEEE Access</source>
					<volume>6</volume>
					<fpage>5199</fpage>
					<lpage>5207</lpage>
					<year>2018</year>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1109/access.2018.2789522">https://doi.org/10.1109/access.2018.2789522</ext-link>
				</element-citation>
			</ref>
			<ref id="B15">
				<label>[15]</label>
				<mixed-citation>[15] J.-O. Lee, Y.-S. Kim, S.-I. Moon, &quot;Current Injection Power Flow Analysis and Optimal Generation Dispatch for Bipolar DC Microgrids,&quot; IEEE Transactions on Smart Grid, vol. 12, pp. 1918-1928, 2021. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1109/tsg.2020.3046733">https://doi.org/10.1109/tsg.2020.3046733</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Lee</surname>
							<given-names>J.-O.</given-names>
						</name>
						<name>
							<surname>Kim</surname>
							<given-names>Y.-S.</given-names>
						</name>
						<name>
							<surname>Moon</surname>
							<given-names>S.-I.</given-names>
						</name>
					</person-group>
					<article-title>Current Injection Power Flow Analysis and Optimal Generation Dispatch for Bipolar DC Microgrids</article-title>
					<source>IEEE Transactions on Smart Grid</source>
					<volume>12</volume>
					<fpage>1918</fpage>
					<lpage>1928</lpage>
					<year>2021</year>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1109/tsg.2020.3046733">https://doi.org/10.1109/tsg.2020.3046733</ext-link>
				</element-citation>
			</ref>
			<ref id="B16">
				<label>[16]</label>
				<mixed-citation>[16] J. Kim, J. Cho, H. Kim, Y. Cho, H. Lee, &quot;Power Flow Calculation Method of DC Distribution Network for Actual Power System,&quot; KEPCO Journal on Electric Power and Energy, vol. 6, pp. 419-425, 2020. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.18770/KEPCO.2020.06.04.419">https://doi.org/10.18770/KEPCO.2020.06.04.419</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Kim</surname>
							<given-names>J.</given-names>
						</name>
						<name>
							<surname>Cho</surname>
							<given-names>J.</given-names>
						</name>
						<name>
							<surname>Kim</surname>
							<given-names>H.</given-names>
						</name>
						<name>
							<surname>Cho</surname>
							<given-names>Y.</given-names>
						</name>
						<name>
							<surname>Lee</surname>
							<given-names>H.</given-names>
						</name>
					</person-group>
					<article-title>Power Flow Calculation Method of DC Distribution Network for Actual Power System</article-title>
					<source>KEPCO Journal on Electric Power and Energy</source>
					<volume>6</volume>
					<fpage>419</fpage>
					<lpage>425</lpage>
					<year>2020</year>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.18770/KEPCO.2020.06.04.419">https://doi.org/10.18770/KEPCO.2020.06.04.419</ext-link>
				</element-citation>
			</ref>
			<ref id="B17">
				<label>[17]</label>
				<mixed-citation>[17] O. D. Montoya, Á. Medina-Quesada, W. Gil-González, &quot;Solving the Power Flow Problem in Bipolar DC Asymmetric Distribution Networks Using Broyden’s Method,&quot; Sensors, vol. 23, e6704, 2023.</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Montoya</surname>
							<given-names>O. D.</given-names>
						</name>
						<name>
							<surname>Medina-Quesada</surname>
							<given-names>Á.</given-names>
						</name>
						<name>
							<surname>Gil-González</surname>
							<given-names>W.</given-names>
						</name>
					</person-group>
					<article-title>Solving the Power Flow Problem in Bipolar DC Asymmetric Distribution Networks Using Broyden’s Method</article-title>
					<source>Sensors</source>
					<volume>23</volume>
					<size units="pages">e6704</size>
					<year>2023</year>
				</element-citation>
			</ref>
			<ref id="B18">
				<label>[18]</label>
				<mixed-citation>[18] J.-O. Lee, Y.-S. Kim, J.-H. Jeon, &quot;Generic power flow algorithm for bipolar DC microgrids based on Newton-Raphson method,&quot; International Journal of Electrical Power &amp; Energy Systems, vol. 142, e108357, 2022.</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Lee</surname>
							<given-names>J.-O.</given-names>
						</name>
						<name>
							<surname>Kim</surname>
							<given-names>Y.-S.</given-names>
						</name>
						<name>
							<surname>Jeon</surname>
							<given-names>J.-H.</given-names>
						</name>
					</person-group>
					<article-title>Generic power flow algorithm for bipolar DC microgrids based on Newton-Raphson method</article-title>
					<source>International Journal of Electrical Power &amp; Energy Systems</source>
					<volume>142</volume>
					<size units="pages">e108357</size>
					<year>2022</year>
				</element-citation>
			</ref>
			<ref id="B19">
				<label>[19]</label>
				<mixed-citation>[19] S. Sepúlveda-García, O. D. Montoya, A. Garcés, &quot;A second-order conic approximation to solving the optimal power flow problem in bipolar DC networks while considering a high penetration of distributed energy resources,&quot; International Journal of Electrical Power &amp; Energy Systems, vol. 155, e109516, 2024.</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Sepúlveda-García</surname>
							<given-names>S.</given-names>
						</name>
						<name>
							<surname>Montoya</surname>
							<given-names>O. D.</given-names>
						</name>
						<name>
							<surname>Garcés</surname>
							<given-names>A.</given-names>
						</name>
					</person-group>
					<article-title>A second-order conic approximation to solving the optimal power flow problem in bipolar DC networks while considering a high penetration of distributed energy resources</article-title>
					<source>International Journal of Electrical Power &amp; Energy Systems</source>
					<volume>155</volume>
					<size units="pages">e109516</size>
					<year>2024</year>
				</element-citation>
			</ref>
			<ref id="B20">
				<label>[20]</label>
				<mixed-citation>[20] C. Hernandez, W. Sánchez Huertas, V. Gómez, &quot;Optimal Power Flow through Artificial Intelligence Techniques,&quot; Tecnura, vol. 25, pp. 150-170, 2021. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.14483/22487638.18245">https://doi.org/10.14483/22487638.18245</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Hernandez</surname>
							<given-names>C.</given-names>
						</name>
						<name>
							<surname>Huertas</surname>
							<given-names>W. Sánchez</given-names>
						</name>
						<name>
							<surname>Gómez</surname>
							<given-names>V.</given-names>
						</name>
					</person-group>
					<article-title>Optimal Power Flow through Artificial Intelligence Techniques</article-title>
					<source>Tecnura</source>
					<volume>25</volume>
					<fpage>150</fpage>
					<lpage>170</lpage>
					<year>2021</year>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.14483/22487638.18245">https://doi.org/10.14483/22487638.18245</ext-link>
				</element-citation>
			</ref>
			<ref id="B21">
				<label>[21]</label>
				<mixed-citation>[21] O. D. Montoya, V. M. Garrido, W. Gil-Gonzalez, L. F. Grisales-Norena, &quot;Power Flow Analysis in DC Grids: Two Alternative Numerical Methods,&quot; IEEE Transactions on Circuits and Systems II: Express Briefs, vol. 66, pp. 1865-1869, 2019. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1109/tcsii.2019.2891640">https://doi.org/10.1109/tcsii.2019.2891640</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Montoya</surname>
							<given-names>O. D.</given-names>
						</name>
						<name>
							<surname>Garrido</surname>
							<given-names>V. M.</given-names>
						</name>
						<name>
							<surname>Gil-Gonzalez</surname>
							<given-names>W.</given-names>
						</name>
						<name>
							<surname>Grisales-Norena</surname>
							<given-names>L. F.</given-names>
						</name>
					</person-group>
					<article-title>Power Flow Analysis in DC Grids: Two Alternative Numerical Methods</article-title>
					<source>IEEE Transactions on Circuits and Systems II: Express Briefs</source>
					<volume>66</volume>
					<fpage>1865</fpage>
					<lpage>1869</lpage>
					<year>2019</year>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1109/tcsii.2019.2891640">https://doi.org/10.1109/tcsii.2019.2891640</ext-link>
				</element-citation>
			</ref>
			<ref id="B22">
				<label>[22]</label>
				<mixed-citation>[22] O. D. Montoya, W. Gil-González, A. Garcés, &quot;A successive approximations method for power flow analysis in bipolar DC networks with asymmetric constant power terminals,&quot; Electric Power Systems Research, vol. 211, e108264, 2022. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.ijepes.2020.106299">https://doi.org/10.1016/j.ijepes.2020.106299</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Montoya</surname>
							<given-names>O. D.</given-names>
						</name>
						<name>
							<surname>Gil-González</surname>
							<given-names>W.</given-names>
						</name>
						<name>
							<surname>Garcés</surname>
							<given-names>A.</given-names>
						</name>
					</person-group>
					<article-title>A successive approximations method for power flow analysis in bipolar DC networks with asymmetric constant power terminals</article-title>
					<source>Electric Power Systems Research</source>
					<volume>211</volume>
					<size units="pages">e108264</size>
					<year>2022</year>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.ijepes.2020.106299">https://doi.org/10.1016/j.ijepes.2020.106299</ext-link>
				</element-citation>
			</ref>
			<ref id="B23">
				<label>[23]</label>
				<mixed-citation>[23] A. Garcés, &quot;On the Convergence of Newton’s Method in Power Flow Studies for DC Microgrids,&quot; IEEE Transactions on Power Systems, vol. 33, pp. 5770-5777, 2018. <ext-link ext-link-type="uri" xlink:href="https://doi.org/0.1109/tpwrs.2018.2820430">https://doi.org/0.1109/tpwrs.2018.2820430</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Garcés</surname>
							<given-names>A.</given-names>
						</name>
					</person-group>
					<article-title>On the Convergence of Newton’s Method in Power Flow Studies for DC Microgrids</article-title>
					<source>IEEE Transactions on Power Systems</source>
					<volume>33</volume>
					<fpage>5770</fpage>
					<lpage>5777</lpage>
					<year>2018</year>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/0.1109/tpwrs.2018.2820430">https://doi.org/0.1109/tpwrs.2018.2820430</ext-link>
				</element-citation>
			</ref>
			<ref id="B24">
				<label>[24]</label>
				<mixed-citation>[24] M. C. Herrera-Briñez, O. D. Montoya, L. Alvarado-Barrios, H. R. Chamorro, &quot;The Equivalence between Successive Approximations and Matricial Load Flow Formulations,&quot; Applied Sciences, vol. 11, e2905, 2021. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.3390/app11072905">https://doi.org/10.3390/app11072905</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Herrera-Briñez</surname>
							<given-names>M. C.</given-names>
						</name>
						<name>
							<surname>Montoya</surname>
							<given-names>O. D.</given-names>
						</name>
						<name>
							<surname>Alvarado-Barrios</surname>
							<given-names>L.</given-names>
						</name>
						<name>
							<surname>Chamorro</surname>
							<given-names>H. R.</given-names>
						</name>
					</person-group>
					<article-title>The Equivalence between Successive Approximations and Matricial Load Flow Formulations</article-title>
					<source>Applied Sciences</source>
					<volume>11</volume>
					<size units="pages">e2905</size>
					<year>2021</year>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.3390/app11072905">https://doi.org/10.3390/app11072905</ext-link>
				</element-citation>
			</ref>
			<ref id="B25">
				<label>[25]</label>
				<mixed-citation>[25] L. Paniagua, R. B. Prada, &quot;Voltage stability assessment using equivalent Thevenin,&quot; in IEEE Thirty Fifth Central American and Panama Convention (CONCAPAN XXXV), 2015. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1109/concapan.2015.7428499">https://doi.org/10.1109/concapan.2015.7428499</ext-link>
				</mixed-citation>
				<element-citation publication-type="confproc">
					<person-group person-group-type="author">
						<name>
							<surname>Paniagua</surname>
							<given-names>L.</given-names>
						</name>
						<name>
							<surname>Prada</surname>
							<given-names>R. B.</given-names>
						</name>
					</person-group>
					<source>Voltage stability assessment using equivalent Thevenin</source>
					<conf-name>IEEE Thirty Fifth Central American and Panama Convention (CONCAPAN XXXV)</conf-name>
					<year>2015</year>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1109/concapan.2015.7428499">https://doi.org/10.1109/concapan.2015.7428499</ext-link>
				</element-citation>
			</ref>
			<ref id="B26">
				<label>[26]</label>
				<mixed-citation>[26] O. D. Montoya, W. Gil-González, A. Garces, &quot;Numerical methods for power flow analysis in DC networks: State of the art, methods and challenges,&quot; International Journal of Electrical Power &amp; Energy Systems, vol. 123, e106299, 2020.</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Montoya</surname>
							<given-names>O. D.</given-names>
						</name>
						<name>
							<surname>Gil-González</surname>
							<given-names>W.</given-names>
						</name>
						<name>
							<surname>Garces</surname>
							<given-names>A.</given-names>
						</name>
					</person-group>
					<article-title>Numerical methods for power flow analysis in DC networks: State of the art, methods and challenges</article-title>
					<source>International Journal of Electrical Power &amp; Energy Systems</source>
					<volume>123</volume>
					<size units="pages">e106299</size>
					<year>2020</year>
				</element-citation>
			</ref>
			<ref id="B27">
				<label>[27]</label>
				<mixed-citation>[27] J. W. Simpson-Porco, F. Dorfler, F. Bullo, &quot;On Resistive Networks of Constant-Power Devices,&quot; IEEE Transactions on Circuits and Systems II: Express Briefs, vol. 62, pp. 811-815, 2015. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1109/tcsii.2015.2433537">https://doi.org/10.1109/tcsii.2015.2433537</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Simpson-Porco</surname>
							<given-names>J. W.</given-names>
						</name>
						<name>
							<surname>Dorfler</surname>
							<given-names>F.</given-names>
						</name>
						<name>
							<surname>Bullo</surname>
							<given-names>F.</given-names>
						</name>
					</person-group>
					<article-title>On Resistive Networks of Constant-Power Devices</article-title>
					<source>IEEE Transactions on Circuits and Systems II: Express Briefs</source>
					<volume>62</volume>
					<fpage>811</fpage>
					<lpage>815</lpage>
					<year>2015</year>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1109/tcsii.2015.2433537">https://doi.org/10.1109/tcsii.2015.2433537</ext-link>
				</element-citation>
			</ref>
			<ref id="B28">
				<label>[28]</label>
				<mixed-citation>[28] P. Huamaní Navarrete, &quot;Programación de interfaz gráfica en APP Designer del MATLAB para representar la serie de Fourier en curso introductorio de telecomunicaciones,&quot; Scientia, vol. 23, pP. 199-213, 2023. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.31381/scientia.v23i23.4592">https://doi.org/10.31381/scientia.v23i23.4592</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Navarrete</surname>
							<given-names>P. Huamaní</given-names>
						</name>
					</person-group>
					<article-title>Programación de interfaz gráfica en APP Designer del MATLAB para representar la serie de Fourier en curso introductorio de telecomunicaciones</article-title>
					<source>Scientia</source>
					<volume>23</volume>
					<fpage>199</fpage>
					<lpage>213</lpage>
					<year>2023</year>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.31381/scientia.v23i23.4592">https://doi.org/10.31381/scientia.v23i23.4592</ext-link>
				</element-citation>
			</ref>
			<ref id="B29">
				<label>[29]</label>
				<mixed-citation>[29] D. Murillo-Yarce, A. Garcés-Ruiz, A. Escobar-Mejía, &quot;Passivity-Based Control for DC-Microgrids with Constant Power Terminals in Island Mode Operation,&quot; Revista Facultad de Ingeniería Universidad de Antioquia, pp. 32-39, 2018. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.17533/udea.redin.n86a05">https://doi.org/10.17533/udea.redin.n86a05</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Murillo-Yarce</surname>
							<given-names>D.</given-names>
						</name>
						<name>
							<surname>Garcés-Ruiz</surname>
							<given-names>A.</given-names>
						</name>
						<name>
							<surname>Escobar-Mejía</surname>
							<given-names>A.</given-names>
						</name>
					</person-group>
					<article-title>Passivity-Based Control for DC-Microgrids with Constant Power Terminals in Island Mode Operation</article-title>
					<source>Revista Facultad de Ingeniería Universidad de Antioquia</source>
					<fpage>32</fpage>
					<lpage>39</lpage>
					<year>2018</year>
					<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.17533/udea.redin.n86a05">https://doi.org/10.17533/udea.redin.n86a05</ext-link>
				</element-citation>
			</ref>
		</ref-list>
		<fn-group>
			<fn fn-type="other" id="fn1">
				<label>Citation:</label>
				<p> O.-D. Montoya-Giraldo, J.-C. Rocha, D. Fontecha-Saboya, “Development of an Application for Calculating the Power Flow of Bipolar DC Networks Using the MATLAB Environment,” <italic>Revista Facultad de Ingeniería</italic>, vol. 33, no. 67, e17362, 2024. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.19053/01211129.v33.n67.2024.17362">https://doi.org/10.19053/01211129.v33.n67.2024.17362</ext-link>
				</p>
			</fn>
		</fn-group>
	</back>