Skip to main navigation menu Skip to main content Skip to site footer

Dielectric strength test to protection elements for live lines works

Abstract

This paper presents the design and assembly of a system of tests of sustained voltage to elements and equipment used in live line maneuvers through tests on gloves and dielectric rods, as these are the first points of contact to ensure safe operations. It means an advance for the creation of a laboratory certified in this type of tests at Universidad Pedagógica y Tecnológica de Colombia (UPTC) Faculty of Duitama, considering that currently there are not laboratories that provide this service in Boyacá and Casanare. Dielectric strength tests were performed on personal protection elements and equipment under the parameters of ASTM D120, ASTM F496, ISO 60903, ASTM-F711 and IEEE 978, developing an assembly for testing gloves and dielectric rods with voltage levels up to 15 kV. The results validate the proposed system to outlook of circuit design and implementation, where tests were performed to establish dielectric capacities, in operating under open circuit conditions, with resistive load or short circuit. The compliance with the regulations established under the test sequences of safety parameters for the system and the follow-up to the tests was verified through the use of a management system for the generation of concepts of approval or rejection of the tested elements.

Keywords

Dielectric strength, works with voltage (JWV), sustained voltage

PDF (Español)

References

  • Ministerio de Minas y Energía, Reglamento Técnico de Instalaciones eléctricas RETIE. Bogotá: MME, 2015.
  • Comisión de Regulación de Energía y Gas CREG. (2016). Resolución CREG-070 de 1998, CREG 179 de 2014 y CREG 024 de 2016 Asignación de obligaciones de energía firme del cargo por confiabilidad. [En línea]. Disponible: http://www.creg.gov. co/cxc/secciones/documentos/resoluciones.htm.
  • Ministerio de la Protección Social, de Colombia. (2009). Resolución 001348 de 2009. [En línea]. Disponible: http://www.alcaldiabogota.gov.co/sisjur/ normas/Norma1.jsp?i=36213.
  • Organismo Nacional de Acreditación-ONAC. (s.f.). [En línea]. Disponible en http://www.onac.org.co/
  • Norma Técnica Colombiana NTC-ISO/IEC 17025. Requisitos generales para la competencia de los laboratorios de ensayo y calibración.
  • ASTM D 120. (s.f.). Standard specification for rubber gloves. Disponible en los formatos ASTM. O [En línea]. Disponible: http://www.astm.org.
  • UNE-EN 60903:2005. (2005). Trabajos en tensión. Guantes de material aislante. [En línea]. Disponible: http://www.insht.es/InshtWeb/Contenidos/Documentacion/TextosOnline/Divulgacion_Normativa/Ficheros/FDN_20.pdf.
  • Matrimol S.A.S. (s.f.). Nombre de pruebas en matrimol, Universidad del Valle. [En línea]. http://matrimol.com/pruebaslab.php.
  • IEEE 978 de 1984, “Guide for in service maintenance and electrical testing of line lives tools”, 1984.
  • ASTM F711 (s.f.). Standar specification for in- service care of Insulating Gloves and Sleeves. [En línea]. Disponible: http://www.astm.org
  • IEC 855 de 1985, “Insulatingfoam-filled tubes & solid rods for live working”, 1985. [12] IEC 832 de 1988, “Insulting poles (insulatin sticks) & universal tool attachements for live work”, 1988.
  • IEC 410 de 1973.
  • IEEE 978 de 1984, “Guide for in-service maintenance and electrical testing of live-line tools”, 1984.
  • N. Kolcio y R.A. Peszlen, “Electrical Aspects of Testing Insulating Gloves”, IEEE Transactions on Power Apparatus and Systems, vol.PAS-102, n.º 7, p. 2364–2368, Feb. 26 2007. DOI: 10.1109/ TPAS.1983.318163. DOI: https://doi.org/10.1109/TPAS.1983.318163
  • H. Ospina, “Control predictivo para la detección de alarmas en pruebas de aislamiento de Pértigas utilizadas en redes de distribución”, Revista Energía y Computación, vol. 17 n.º 1, págs.5-6, 2009.
  • M. Balpinarli, J.J. Dai y G. Gela, “AC and DC breakdown versus thickness characteristics for rubber gloves”, IEEE transactions on power delivery, vol. 3 n.º 1, pp. 384-391, 1988. DOI: https://doi.org/10.1109/61.4268
  • M. S. A. A. Hammam, N. Yoshimura, W. Brockway, G. Adams, A. Fini and H. Nowak, “Puncture breakdown characteristics of protected rubber insulating gloves”, IEEE transactions on power delivery, vol. 5 n.º 2, pp. 538-547, 1990. DOI: https://doi.org/10.1109/61.53055
  • C.E. Pinto-Salamanca, Diseño y montaje de un sistema de pruebas dieléctricas en guantes y pértigas hasta 15 kV. Duitama: libro, resultado de trabajo de grado, 2016. [20] M. Pinto, “Uso de la robótica educativa como herramienta en los procesos de enseñanza”, Ingeniería Investigación y Desarrollo, vol. 10 n.º 1, pág. 16-20, enero-junio de 2010
  • M. Pinto, “Determinación de parámetros de un robot móvil de lego mindstorms®”, Ingeniería Investigación y Desarrollo , vol. 5 n.º 2, págs. 10-12, julio-diciembre de 2007.

Downloads

Download data is not yet available.